Danaher has been granted a patent for a light source module for microscopes. The module includes a light source, light blocking shutter, and light sensor integrated with the shutter. The sensor detects light intensity along the path, enhancing precision and control in microscopy applications. GlobalData’s report on Danaher gives a 360-degree view of the company including its patenting strategy. Buy the report here.

Smarter leaders trust GlobalData

Report-cover

Data Insights Danaher Corp - Company Profile

Buy the Report

Data Insights

The gold standard of business intelligence.

Find out more

According to GlobalData’s company profile on Danaher, Laboratory automation robots was a key innovation area identified from patents. Danaher's grant share as of January 2024 was 57%. Grant share is based on the ratio of number of grants to total number of patents.

Integrated light sensor and shutter for microscope light source

Source: United States Patent and Trademark Office (USPTO). Credit: Danaher Corp

A recently granted patent (Publication Number: US11885950B2) discloses a light source module designed for microscopes. The module includes a light source emitting illumination light, a light blocking shutter that can be moved in and out of the light path, and a light sensor integrated with the shutter to detect the intensity of the light. The patent also describes a method for illuminating a sample using this module, where the light source is controlled based on the intensity detected by the sensor to prevent excessive light exposure to the sample. Additionally, a calibration method is outlined, involving emitting light, detecting intensity, and determining calibration characteristics for the module.

Furthermore, the patent details the integration of multiple light sources and a beam combiner in the module to provide a combined illumination light. The module includes a controller to manage the light sensor and source, adjusting the intensity of the emitted light accordingly. The method for illuminating a sample involves a sequence of steps including moving the light blocking shutter, emitting light, detecting intensity, and adjusting the light source. Additionally, a predictive maintenance procedure is described, where the light source emits light at maximum intensity, and maintenance information is generated based on the detected intensity. The calibration method involves emitting light, detecting intensity, and determining calibration characteristics based on reference power and intensity values.

To know more about GlobalData’s detailed insights on Danaher, buy the report here.

Data Insights

From

The gold standard of business intelligence.

Blending expert knowledge with cutting-edge technology, GlobalData’s unrivalled proprietary data will enable you to decode what’s happening in your market. You can make better informed decisions and gain a future-proof advantage over your competitors.

GlobalData

GlobalData, the leading provider of industry intelligence, provided the underlying data, research, and analysis used to produce this article.

GlobalData Patent Analytics tracks bibliographic data, legal events data, point in time patent ownerships, and backward and forward citations from global patenting offices. Textual analysis and official patent classifications are used to group patents into key thematic areas and link them to specific companies across the world’s largest industries.